Skip to content
ClapeyronThermoPublic

About

Nonlinear pinch point solver for HP-ORC systems

Resources

Stars

11 stars

Watchers

1 watching

Forks

Latest commit

 

History

373 Commits

Folders and files

Repository files navigation

Carnot.jl

Build Status Dev

Carnot Logo

Note

Carnot.jl was previously ThermoCycleGlides.jl. It has been rename to a more representable name for modeling thermodynamic cycles.

This package aims to solve Heat Pump and ORC systems for given known temperature glides. For now it is robust for sub-critical cycles.

The thermodynamic computations use Clapeyron.jl.

Installation

For the latest release, first type ] and then:

pkg> add Carnot

For the developer version type:

pkg> add https://github.com/ClapeyronThermo/Carnot.jl

Usage

Usage Heat Pump Example :

 using Clapeyron, Carnot

 fluid = cPR(["R134a"],idealmodel = ReidIdeal);

 η_comp = 0.75; pp_cond = 5; pp_evap = 5;

 T_evap_in = 273.15 + 20; T_evap_out = 273.15 + 0; 
 
 T_cond_in = 273.15 + 30;  T_cond_out = 273.15+60;

 ΔT_sc = 15; ΔT_sh = 10;

 hp = HeatPump(fluid=fluid,z=[1.0],
                T_evap_in=T_evap_in,T_evap_out = T_evap_out,
                T_cond_in = T_cond_in,T_cond_out=T_cond_out,
                η_comp=η_comp,
                pp_evap=pp_evap,pp_cond=pp_cond,
                ΔT_sc = ΔT_sc,ΔT_sh = ΔT_sh);

To solve do the following:

julia>  sol_hp = solve(hp,ThermoCycleParameters(autodiff=false))
SolutionState{Float64, Int64}([2.3994048422328, 16.817386905557985], 20, 4, [5.935589797445573e-10, 3.0524915928253904e-11], [1.6183989368988956, 1.6183989368988956], [26.13980387599181, 26.13980387599181], false, 2, 8.149495449471192e-7, 5.943433628196976e-10, :subcritical)

julia> COP(hp,sol_hp)
-3.445859140654867

To plot do the following:

julia>  using Plots
julia>  default(
                  fontfamily = "DejaVu Sans",
                  guidefontsize = 14,
                  tickfontsize = 11,
                  legendfontsize = 11,
                  titlefontsize = 14,
                  dpi = 500,
                  framestyle = :box
              )
julia>  plot(hp,sol_hp,N = 100)

HP_cyclopentane

Limitation

  1. Fluid models are limited to the ones provided by default in Clapeyron.jl. Now restricted to CubicModel and SingleFluid models.
  2. For now the solver is stable for sub-critical parameters. So if incase the solver does not converge please check if the parameters provided allow the solution to be subcritical.
  3. For mixtures, it is recommended to use parameters sufficently below the critical point as sometimes near crictical zone the computation of dew and bubble points can fail.
  4. If for solving with autodiff = true, the first run will have significant compilation time. The subsequent runs will be faster.

About

Nonlinear pinch point solver for HP-ORC systems

Resources

Stars

11 stars

Watchers

1 watching

Forks

Releases

Packages

Used by

Contributors

Languages