Scope: Documentation in repositories maintained by the VizHub organization. These are editorial and verification standards, not requirements to adopt a particular framework or application architecture.
Maintainer note: This public repository must not disclose the names, source contents, credentials, operations, or roadmaps of private repositories.
Documentation should let a new reader answer five questions without guessing:
- What is this repository? State its purpose, intended audience, and relation to VizHub.
- What is its actual status? Distinguish active, maintenance-only, experimental, historical, and archived work based on verified evidence.
- How do I use or develop it? Provide commands and examples that correspond to checked-in scripts and actual exported interfaces.
- Where do I find deeper information? Use a small, accurate navigation structure and canonical links.
- What are its limitations? Clearly separate supported behavior from proposals, experiments, and legacy instructions.
Use the most complete, accurate, maintained documentation as a quality reference, not as text to copy indiscriminately. The appropriate size of the documentation depends on the repository.
Use these sections as a checklist, not as a rigid template. A small library may need only a short README; a deployed application may need a separate documentation index.
- Title and one-paragraph summary: Explain what the project does; avoid aspirational feature claims.
- Status and scope: Explicitly label historical or experimental repositories; verify active support rather than inferring it from recent push dates.
- Quick start or usage: Show the minimum reproducible workflow, with prerequisites and environment assumptions.
- Key features / API: Only describe functionality confirmed by source, tests, or a maintained example.
- Development and verification: List commands actually present in the package manifest or tooling configuration, and warn about destructive commands.
- Architecture / design: Link to deeper documentation when necessary; avoid duplicating implementation details.
- Related projects: Link to relevant public repositories and the public repository catalog.
- Contributing and license: Link to actual contribution and license files, if present; do not invent a license or contribution policy.
Avoid adding placeholder sections. When functionality is not verified, omit it or mark it as unverified and explain what needs checking.
- Read the default branch's README, relevant package manifests, scripts, exports, routes, configuration, tests, and existing documents before editing.
- Code, tests, and checked-in configuration win when a README disagrees with them. Record unresolved discrepancies in the PR rather than guessing.
- Validate example commands against the repository's scripts, expected working directory, and required tooling. A
READMEexample is not verified merely because it looks plausible. - Do not claim a feature is deployed, enabled, or available to customers simply because its code exists or a PR merged. Document source state, deployment evidence, configuration/feature flags, and rollout state separately where relevant.
- Do not copy dates, version numbers, benchmark results, pricing, uptime, API endpoints, or feature matrices from older documents without verification.
- If evidence is unavailable, write “not verified” rather than inventing an assertion.
- Use last pushed only as repository activity metadata. It is not proof of active maintenance, a default-branch merge, or a production deployment.
- VizHub is the user-facing product name at vizhub.com. Keep existing technical repository identifiers intact; they are not necessarily product brands.
- VizHub Cloud identifies a legacy product/system. Historical documents should distinguish it from the current VizHub product; do not silently rewrite historical design descriptions.
- VZCode is a separately named editor project. Use its published/project-specific name when referring to that editor.
- Refer to old products, infrastructure, domains, and screenshots in historical context, not as default onboarding or active deployment instructions.
- Prefer links to the actual current GitHub repository. Existing redirects can be retained when verified as intentional; broken or relocated
vizhub-core,datavis-tech, or other legacy links should be assessed individually. - Cross-reference public components through REPOSITORY_CATALOG.md; never imply that every component is currently incorporated into the active product.
- Do not commit credentials, API keys, tokens, internal hostnames, private customer data, billing details, or nonpublic deployment instructions to public documentation.
- Do not reveal or enumerate private repository names in this organization's public documentation. Track private-repository documentation work in a repository with equivalent access controls.
- Use placeholder environment variables, redact sensitive output, and explicitly identify secret-bearing files that must remain uncommitted.
- Tag destructive or production-affecting commands, such as database resets, credential rotation, migrations, and deployments. Never present them as routine setup commands without context and safety checks.
- Avoid source-code, dependency, build, or deployment changes in documentation-only PRs, unless separately approved.
- Keep the README a compact, reliable entry point. Move long-form reference material into well-named documents when it improves findability.
- If a repository already has documentation indexes or
AGENTS.mdinstructions, link to them rather than creating competing indexes. - Prefer relative links inside the same repository and canonical GitHub links across repositories.
- Fix broken anchors, paths, and links. Do not delete useful historical design notes merely because they are old: label and relocate them where appropriate.
- Treat plans and proposals as plans, not confirmed behavior. Include a date or version/context when claims are time-sensitive.
- Avoid unmaintained counts and manually numbered “complete” inventories that will drift unless a clear maintenance process exists.
Every Wave 1–3 documentation PR should address the applicable checks:
- Changes are confined to documentation and necessary documentation assets.
- README identifies the repository's purpose, audience, and verified status.
- Installation, test, and development commands match the checked-in scripts/configuration, or are clearly marked unverified.
- Technical assertions are supported by implementation, tests, or other explicit evidence.
- User-facing product terminology and cross-repository links are consistent.
- Historical features and old deployment endpoints are not described as current.
- New and changed relative links, image references, and Markdown anchors are checked.
- No secrets, private repo names, private infrastructure details, or sensitive customer information are disclosed.
- Any available documentation validation is run; unavailable checks are explicitly noted.
- The PR describes changes, evidence, limitations, and any follow-on documentation-only work.
| Repository type | Typical documentation |
|---|---|
| Small library / theme | README with installation, usage, API, examples, status |
| Editor / SDK / runtime | README plus API/architecture or integration docs as needed |
| App / service | README, environment/setup, architecture, testing, operations docs separated by access level |
| Template / example | README with reproducible starting point, prerequisites, customization, examples |
| Historical / abandoned experiment | README explaining purpose, historical period, reproducibility if possible, and current alternatives |
| Archived repository | Preserve archived state; catalog it here. A documentation PR requires unarchiving by an authorized maintainer |
See Documentation rollout for the sequence and review process.