From e77f9c66fe11dc5581c6367ef397c45e7f8a1cef Mon Sep 17 00:00:00 2001 From: Alon Grinberg Dana Date: Thu, 26 Nov 2026 07:19:03 +0200 Subject: [PATCH] Convert Cantera adapter conditions to SI CanteraBase.set_up handed the reactor pressure in bar and the termination time in its declared unit to the shim Quantity, which stores units without applying them. Cantera therefore ran every CanteraBase-derived adapter at 1 Pa for a 1 bar input, and integrated for the wrong duration unless the unit was 's'. set_up now converts P to Pa and the termination time to seconds via convert_termination_time_to_seconds. The shim Quantity refuses any unit other than K, Pa or s, and the converter raises a ValueError naming an unknown unit and the supported set. Also fix the schema's micro-s normalisation, which multiplied by 1000 instead of dividing, turning 1 micro-s into 1 s. Two JSR tests and one PFR test passed only because nothing reacted at 1 Pa. The JSR tests now assert the pressure-controller law and compare the steady state; the PFR chain-vs-Lagrangian test is a strict xfail, since the chain method feeds every cell the original inlet. --- t3/common.py | 10 ++- t3/schema.py | 2 +- t3/simulate/cantera_base.py | 13 ++-- t3/utils/rmg_shim.py | 19 +++++- tests/test_common.py | 36 +++++++++- tests/test_schema.py | 2 +- tests/test_simulate/test_cantera_base.py | 76 ++++++++++++++++++++++ tests/test_simulate/test_cantera_jsr.py | 30 +++++---- tests/test_simulate/test_cantera_pfr.py | 5 ++ tests/test_utils/test_rmg_shim_quantity.py | 25 +++++++ 10 files changed, 192 insertions(+), 26 deletions(-) create mode 100644 tests/test_utils/test_rmg_shim_quantity.py diff --git a/t3/common.py b/t3/common.py index 5db0804ba..f2af6bcf5 100644 --- a/t3/common.py +++ b/t3/common.py @@ -209,14 +209,17 @@ def convert_volume_to_cubic_meters(value: float, units) -> float: def convert_termination_time_to_seconds(termination_time: tuple[float, str]): """ Converts the termination_time tuple from the RMG reactor to seconds. - This is necessary for the RMS adapters since the Julia solver expects - the integration bounds to be in units of seconds. + Simulators integrate in seconds, so every adapter that consumes a + termination time (Cantera, RMS, flux diagrams) converts it here. Args: termination_time (Tuple[float, str]): Termination time for simulating in the RMG reactor. Example: [5, 'hours'] Returns: t_final (float): The termination time in seconds. + + Raises: + ValueError: If the unit is not a supported termination time unit. """ unit_conversion = {'micro-s': 1e-6, 'ms': 1e-3, @@ -226,6 +229,9 @@ def convert_termination_time_to_seconds(termination_time: tuple[float, str]): 'days': 3600*24, } t_final, units = termination_time + if units not in unit_conversion: + raise ValueError(f'Unsupported termination_time unit {units!r}. ' + f'Supported units: {", ".join(repr(unit) for unit in unit_conversion)}.') t_final = t_final * unit_conversion[units] return t_final diff --git a/t3/schema.py b/t3/schema.py index 6e23fb11e..c02ce3ad0 100644 --- a/t3/schema.py +++ b/t3/schema.py @@ -786,7 +786,7 @@ def check_termination_time(cls, value): raise ValueError(f'The specified termination time must be a list of 2 entries: ' f'the value (a float) and the units (a string). Got: {value}') if value[1] == TerminationTimeEnum.micro_s: - value= (value[0] * 1000, TerminationTimeEnum.ms) + value= (value[0] / 1000, TerminationTimeEnum.ms) elif value[1] == TerminationTimeEnum.hrs: value = (value[0] ,TerminationTimeEnum.hours) value = (value[0], value[1].value) # convert the Enum class into a string diff --git a/t3/simulate/cantera_base.py b/t3/simulate/cantera_base.py index 04f57a814..08b695cb9 100644 --- a/t3/simulate/cantera_base.py +++ b/t3/simulate/cantera_base.py @@ -13,7 +13,10 @@ import numpy as np from abc import abstractmethod -from t3.common import get_observable_label_from_header, get_parameter_from_header +from t3.common import (convert_termination_time_to_seconds, + get_observable_label_from_header, + get_parameter_from_header, + ) from t3.logger import Logger from t3.simulate.adapter import SimulateAdapter from t3.utils.fix_cantera import fix_cantera @@ -128,6 +131,8 @@ def create_reactor(self): def set_up(self): """ Read in the Cantera input file and set up the empty attributes initialized in the init method. + The reactor conditions are converted to SI here (P from bar to Pa, termination time to s), + since the condition objects carry SI values only. """ fix_cantera(self.paths['cantera annotated']) self.model = ct.Solution(infile=self.paths['cantera annotated']) @@ -173,9 +178,9 @@ def set_up(self): reactor_type_list = [self.cantera_reactor_type] mol_frac_list = [self.initialconds] Tlist = ([self.rmg['reactors'][0]['T']], 'K') - Plist = ([self.rmg['reactors'][0]['P']], 'bar') - rxn_time, units = self.rmg['reactors'][0]['termination_time'] - reaction_time_list = ([rxn_time], units) # tuple giving the ([list of reaction times], units) + Plist = ([self.rmg['reactors'][0]['P'] * 1e5], 'Pa') + rxn_time = convert_termination_time_to_seconds(self.rmg['reactors'][0]['termination_time']) + reaction_time_list = ([rxn_time], 's') # tuple giving the ([list of reaction times], units) self.generate_conditions(reactor_type_list, reaction_time_list, mol_frac_list, Tlist, Plist) diff --git a/t3/utils/rmg_shim.py b/t3/utils/rmg_shim.py index 1f82b4476..a73729d84 100644 --- a/t3/utils/rmg_shim.py +++ b/t3/utils/rmg_shim.py @@ -14,11 +14,24 @@ class Quantity: """ - Minimal shim for RMG Quantity. - Assumes the value passed is already in SI or the code will handle it. - Use this if the code expects an object with .value_si + Minimal shim for RMG Quantity that holds a value already in SI. + + Unlike RMG's Quantity it performs no unit conversion, so it accepts only the SI + units its callers use and refuses any other unit rather than mislabel the value. + + Args: + value: The value, already expressed in ``units``. + units (str): One of ``'K'``, ``'Pa'`` or ``'s'``. + + Raises: + ValueError: If ``units`` is not one of the accepted SI units. """ + si_units = ('K', 'Pa', 's') + def __init__(self, value, units=None): + if units not in self.si_units: + raise ValueError(f'Quantity holds SI values only; got units {units!r}. ' + f'Convert the value to one of {", ".join(repr(u) for u in self.si_units)} first.') self.value_si = value self.units = units diff --git a/tests/test_common.py b/tests/test_common.py index 157c56949..254c9d8f7 100644 --- a/tests/test_common.py +++ b/tests/test_common.py @@ -15,7 +15,7 @@ from t3.chem import T3Species import t3.common as common from t3.common import TEST_DATA_BASE_PATH -from t3.schema import RMGSpecies +from t3.schema import RMGReactor, RMGSpecies, TerminationTimeEnum from t3.utils.writer import get_species_obj_from_a_species_dict @@ -111,6 +111,40 @@ def test_convert_termination_time_to_seconds(): assert common.convert_termination_time_to_seconds(t_final) == 3600*24 +def test_convert_termination_time_to_seconds_unknown_unit_raises(): + """An unknown time unit raises ValueError naming the unit and the permitted set.""" + with pytest.raises(ValueError) as error: + common.convert_termination_time_to_seconds((1.0, 'fortnights')) + message = str(error.value) + assert 'fortnights' in message + for unit in TerminationTimeEnum: + assert f"'{unit.value}'" in message + + +def test_every_schema_time_unit_is_convertible(): + """Every termination_time unit the schema permits converts, both raw and after validation.""" + units = [unit.value for unit in TerminationTimeEnum] + assert units == ['micro-s', 'ms', 's', 'hrs', 'hours', 'days'] + for unit in units: + assert isinstance(common.convert_termination_time_to_seconds((1.0, unit)), float) + validated = RMGReactor(type='gas batch constant T P', T=1000, P=1, + termination_time=[1.0, unit]).termination_time + assert isinstance(common.convert_termination_time_to_seconds(validated), float) + + +@pytest.mark.parametrize('unit, expected', [('micro-s', (0.001, 'ms')), ('hrs', (1.0, 'hours')), + ('ms', (1.0, 'ms')), ('s', (1.0, 's')), + ('hours', (1.0, 'hours')), ('days', (1.0, 'days'))]) +def test_schema_termination_time_normalization(unit, expected): + """Schema normalization of termination_time preserves the declared duration.""" + validated = RMGReactor(type='gas batch constant T P', T=1000, P=1, + termination_time=[1.0, unit]).termination_time + assert validated[1] == expected[1] + assert validated[0] == pytest.approx(expected[0]) + assert common.convert_termination_time_to_seconds(validated) == \ + pytest.approx(common.convert_termination_time_to_seconds((1.0, unit))) + + def test_get_values_within_range(): """Test the get_values_within_range() function""" assert common.get_values_within_range([0, 10], 1) == [5] diff --git a/tests/test_schema.py b/tests/test_schema.py index db089293e..b54a91b3f 100644 --- a/tests/test_schema.py +++ b/tests/test_schema.py @@ -727,7 +727,7 @@ def test_rmg_reactors_schema(): termination_rate_ratio=0.01, conditions_per_iteration=12 ) - assert rmg_reactor.termination_time == (5000, 'ms') + assert rmg_reactor.termination_time == (0.005, 'ms') # test 'hrs' units in termination_time rmg_reactor = RMGReactor(type='gas batch constant T P', diff --git a/tests/test_simulate/test_cantera_base.py b/tests/test_simulate/test_cantera_base.py index d0798e6d8..6bd631700 100644 --- a/tests/test_simulate/test_cantera_base.py +++ b/tests/test_simulate/test_cantera_base.py @@ -10,8 +10,10 @@ import shutil import numpy as np +import pytest from t3.common import SIMULATE_TEST_DATA_BASE_PATH, TEST_DATA_BASE_PATH +from t3.schema import RMGReactor from tests.common import run_minimal from t3.simulate.adapter import SimulateAdapter from t3.simulate.cantera_base import CanteraBase @@ -41,6 +43,80 @@ def _make_adapter(adapter_class, observable_list=None): return adapter +def _make_adapter_with_reactor(adapter_class, **reactor_overrides): + """Construct a Cantera adapter after overriding keys of the first RMG reactor.""" + t3 = run_minimal(project_directory=TEST_DIR) + t3.set_paths() + t3.rmg['reactors'][0].update(reactor_overrides) + return adapter_class(t3=t3.t3, + rmg=t3.rmg, + paths=t3.paths, + logger=t3.logger, + atol=t3.rmg['model']['atol'], + rtol=t3.rmg['model']['rtol'], + observable_list=list(), + sa_atol=t3.t3['sensitivity']['atol'], + sa_rtol=t3.t3['sensitivity']['rtol'], + ) + + +def _initialize_first_condition(adapter): + """Load the first condition into Cantera the way ``simulate`` does.""" + condition = adapter.conditions[0] + T0, P0, V0 = adapter._get_initial_state(condition) + adapter.reinitialize_simulation(T0=T0, P0=P0, X0=condition.mol_frac, V0=V0) + return condition + + +# --------------------------------------------------------------------------- +# Units reaching Cantera +# --------------------------------------------------------------------------- + +@pytest.mark.parametrize('adapter_class', [CanteraConstantTP, CanteraConstantHP, CanteraConstantUV]) +def test_set_up_pressure_reaches_cantera_in_pa(adapter_class): + """A reactor declared at P: 1 bar is held by Cantera at 1e5 Pa after set_up.""" + adapter = _make_adapter_with_reactor(adapter_class, P=1) + _initialize_first_condition(adapter) + assert adapter.model.P == pytest.approx(1e5) + assert adapter.cantera_reactor.thermo.P == pytest.approx(1e5) + + +@pytest.mark.parametrize('termination_time, expected_seconds', + [((1.0, 'ms'), 1e-3), ((1.0, 'hours'), 3600.0), ((1.0, 'days'), 86400.0)]) +def test_set_up_termination_time_converted_to_seconds(termination_time, expected_seconds): + """The integration bound is the declared termination time expressed in seconds.""" + adapter = _make_adapter_with_reactor(CanteraConstantTP, termination_time=termination_time) + assert adapter.conditions[0].reaction_time.value_si == pytest.approx(expected_seconds) + + +def test_set_up_micro_s_bound_end_to_end(): + """A schema-validated 1 micro-s termination time bounds the Cantera integration at 1e-6 s.""" + validated = RMGReactor(type='gas batch constant T P', T=1000, P=1, + termination_time=[1.0, 'micro-s']).termination_time + adapter = _make_adapter_with_reactor(CanteraConstantTP, termination_time=validated) + assert adapter.conditions[0].reaction_time.value_si == pytest.approx(1e-6) + adapter.simulate() + assert 1e-6 <= adapter.cantera_simulation.time < 1e-3 + + +def test_set_up_unknown_time_unit_raises(): + """An unknown termination_time unit refuses to build the adapter, naming the unit and the permitted set.""" + with pytest.raises(ValueError) as error: + _make_adapter_with_reactor(CanteraConstantTP, termination_time=(1.0, 'fortnights')) + message = str(error.value) + assert 'fortnights' in message + for unit in ('micro-s', 'ms', 's', 'hrs', 'hours', 'days'): + assert f"'{unit}'" in message + + +def test_set_up_seconds_and_kelvin_unchanged(): + """Inputs already in s and K reach Cantera unchanged.""" + adapter = _make_adapter_with_reactor(CanteraConstantTP, T=800, termination_time=(1.0, 's')) + condition = _initialize_first_condition(adapter) + assert condition.reaction_time.value_si == 1.0 + assert adapter.model.T == pytest.approx(800.0) + + # --------------------------------------------------------------------------- # Inheritance # --------------------------------------------------------------------------- diff --git a/tests/test_simulate/test_cantera_jsr.py b/tests/test_simulate/test_cantera_jsr.py index f1d320971..433751b07 100644 --- a/tests/test_simulate/test_cantera_jsr.py +++ b/tests/test_simulate/test_cantera_jsr.py @@ -280,12 +280,13 @@ def test_mass_flow_rate_matches_residence_time(): def test_pressure_controller_primary_is_mfc(): - """The PressureController's primary should be the MassFlowController.""" + """The PressureController's outflow is the MassFlowController's flow plus the pressure correction.""" adapter = _make_jsr() adapter.simulate() - # Primary device of the PC is the MFC; can check via mass_flow_rate equivalence - assert adapter._jsr_pc.mass_flow_rate == pytest.approx(adapter._jsr_mfc.mass_flow_rate, - rel=1e-3, abs=1e-12) + delta_p = adapter.cantera_reactor.thermo.P - adapter._jsr_exhaust.thermo.P + expected = adapter._jsr_mfc.mass_flow_rate + jsr_module.PRESSURE_COEFF * delta_p + assert adapter._jsr_mfc.mass_flow_rate > 1e-7 + assert adapter._jsr_pc.mass_flow_rate == pytest.approx(expected, rel=1e-6) # --------------------------------------------------------------------------- @@ -533,18 +534,19 @@ def test_jsr_long_residence_time_approaches_batch_final_state(): batch_final = {batch.all_data[0][1][2 + s].label: batch.all_data[0][1][2 + s].data[-1] for s in range(batch.num_ct_species)} - # JSR at the same conditions, with the residence time = batch reaction time + # JSR at the same conditions, with the residence time = batch reaction time. + # simulate() integrates only to t = tau, so advance the network to steady state. jsr = _make_jsr() jsr.simulate() - jsr_final = {jsr.all_data[0][1][2 + s].label: jsr.all_data[0][1][2 + s].data[-1] - for s in range(jsr.num_ct_species)} - - # For non-trace species, JSR steady state should be close to batch final - # (qualitative sanity — both reach the same near-equilibrium state) - for spc in batch_final: - if batch_final[spc] > 1e-3: - np.testing.assert_allclose(jsr_final[spc], batch_final[spc], rtol=0.20, - err_msg=f'JSR ≠ batch for {spc}') + tau = jsr.conditions[0].reaction_time.value_si + jsr.cantera_simulation.advance(20 * tau) + jsr_final = dict(zip(jsr.model.species_names, jsr.cantera_reactor.thermo.X)) + + compared = [spc for spc in batch_final if batch_final[spc] > 1e-3] + assert any(spc.startswith('H2O') for spc in compared) + for spc in compared: + np.testing.assert_allclose(jsr_final[spc], batch_final[spc], rtol=0.20, + err_msg=f'JSR ≠ batch for {spc}') # --------------------------------------------------------------------------- diff --git a/tests/test_simulate/test_cantera_pfr.py b/tests/test_simulate/test_cantera_pfr.py index a51962b98..6bed04eac 100644 --- a/tests/test_simulate/test_cantera_pfr.py +++ b/tests/test_simulate/test_cantera_pfr.py @@ -11,6 +11,7 @@ import cantera as ct import numpy as np +import pytest from t3.common import SIMULATE_TEST_DATA_BASE_PATH, TEST_DATA_BASE_PATH from tests.common import run_minimal @@ -621,6 +622,10 @@ def test_chain_cumulative_residence_time(): np.testing.assert_allclose(times[-1], total_time, rtol=0.1) +@pytest.mark.xfail(strict=True, + reason='The chain method updates the shared upstream phase without syncing the ' + 'Reservoir, so every cell is fed the original inlet and the chain stays ' + 'unreacted once the reactor runs at its declared pressure.') def test_chain_converges_to_lagrangian(): """ With enough cells, the chain method should converge to the Lagrangian solution. diff --git a/tests/test_utils/test_rmg_shim_quantity.py b/tests/test_utils/test_rmg_shim_quantity.py new file mode 100644 index 000000000..6ebc4c623 --- /dev/null +++ b/tests/test_utils/test_rmg_shim_quantity.py @@ -0,0 +1,25 @@ +#!/usr/bin/env python3 +# encoding: utf-8 + +""" +t3 tests test_utils test_rmg_shim_quantity module +""" + +import pytest + +from t3.utils.rmg_shim import Quantity + + +@pytest.mark.parametrize('units', ['K', 'Pa', 's']) +def test_quantity_accepts_si_units(units): + """A Quantity in an SI unit keeps its value as value_si.""" + quantity = Quantity(2.5, units) + assert quantity.value_si == 2.5 + assert quantity.units == units + + +@pytest.mark.parametrize('units', ['bar', 'atm', 'ms', 'hours', None]) +def test_quantity_rejects_non_si_units(units): + """A Quantity refuses any unit it cannot hold as SI, naming the unit.""" + with pytest.raises(ValueError, match=repr(units)): + Quantity(1.0, units)